Appendix A - User Interface Display
313296J 101
Heat Run Screen
The Heat Run screen displays information for four to six
heat zones. See F
IG
. 72 for information about each
zone. For each zone, the icon on the upper right is pres-
ent if the zone is enabled, otherwise the space is blank.
The temperature unit is shown in the upper right of the
menu bar. An alarm icon displays in the bottom right if
there is an alarm or deviation on a heat zone. Press the
soft key under the alarm icon to clear the alarm or devia-
tion.
NOTE: Heat zones five and six are located in the
two-zone expansion kit.
Heat zones seven through ten are located on Ram B.
Heat zones eleven and twelve are located in the
two-zone expansion kit.
The last digit in the temperature control module alarm
codes represents the zone reporting the alarm.
From the Heat Run screen, users can view heat zone
information for each ram, put heat zones into Setback
mode, turn heaters on and off for enabled heat zones,
and change the individual zone temperature settings.
View Heat Zone Information
To view heat zone information, press to
scroll through the Heat Run screens.
NOTE: Must exit edit mode to scroll through the
Heat Run screens.
Setback Mode
To put heaters into setback mode for enabled heat
zones, press . The setpoint for each zone will be
decreased by the setback amount set on Heater Sys-
tem Setup Screen, page 95.
Turn On Heaters
See System Heat Up, page 26, for instructions.
Change Zone Temperature Setting
Press to access the fields to make changes. Use
the navigation buttons to move to the desired heat zone.
Enter the new temperature and press to save the
change. Press to exit edit mode.
Zone
Number
Temperature Control
Module Alarm Code
A1 1
A2 2
A3 3
A4 4
A5 5
A6 6
B1 7
B2 8
B3 9
B4 10
B5 11
B6 12
F
IG
. 72: Heat Run Screen - Ram A
System component
being heated
Zone set point
Zone
number
Current zone temperature
Zobrazit stránku 100