Instructions
LDM5 (Standard) & LDP5 (Preset)
Electronic Metered Dispense Valves
312668W
For metered dispense of oils and antifreeze. For professional use only.
Not approved for use in European explosive atmosphere locations.
Models: See page 2
1000 psi (7 MPa, 69 bar) Maximum Working Pressure
5 gpm (19 lpm) Maximum Flow Rate
1
Important Safety Instructions
Read all warnings and instructions in this manual.
Save these instructions.
NOTICE
This dispense valve:
must be calibrated upon installation (see pages 12
and 19). Dispense amounts will vary with fluid pres-
sure, temperature, and type of fluid being dis-
pensed.
is designed to dispense petroleum-based lubri-
cants and antifreeze only. Do not dispense wind-
shield washer solvent with this dispense valve.
is designed for indoor use only.
•is not designed for in-line installation.
is designed for use with industrial grade batteries,
(see page 31).
LDM5
LDP5
ti12063a
ti12065a
Model 256215 shown
Model 256216 shown
EN
Zobrazit stránku 0
1 2 3 4 5 6 ... 33 34

Shrnutí obsahu

Strany 1 - Instructions

InstructionsLDM5 (Standard) & LDP5 (Preset) Electronic Metered Dispense Valves312668WFor metered dispense of oils and antifreeze. For professional

Strany 2 - 2 312668W

LDM5 Meter Setup and Operation Instructions 10 312668WSetup Menus (FIG. 10)1. If the display is blank (asleep), wake it up by press-ing any button on

Strany 3 - Warnings

LDM5 Meter Setup and Operation Instructions312668W 11Resettable Total (FIG. 11)Resets dispensed total on screen to zero or stores dis-played dispense

Strany 4 - 4 312668W

LDM5 Meter Setup and Operation Instructions 12 312668WCalibration (FIG. 13)Recalibrates the meter for dispensing different fluids.1. If the Calibratio

Strany 5 - Installation

LDM5 Meter Setup and Operation Instructions312668W 13OperationDispensing Fluid in Standard Mode1. If the display was blank (in sleep mode), press and

Strany 6 - Installation Procedure

LDM5 Meter Setup and Operation Instructions 14 312668WViewing TotalsThis is the procedure for viewing the non–resettable and resettable totals in gall

Strany 7 - Connecting Hose to Meter

LDM5 Meter Setup and Operation Instructions312668W 15Error CodeIf an error code is shown on the display, as shown in FIG. 19, you can press the Reset

Strany 8 - 8 312668W

LDP5 Meter Setup and Operation Instructions 16 312668WLDP5 Meter Setup and Operation InstructionsSetupLocking and Unlocking the Trigger To lock the tr

Strany 9 - Keypad Buttons (FIG. 9)

LDP5 Meter Setup and Operation Instructions312668W 17Keypad Buttons (FIG. 22)• Manual / Reset* Used to select Manual Mode dispensing (see Terms). The

Strany 10 - Setup Menus (FIG. 10)

LDP5 Meter Setup and Operation Instructions 18 312668Wc. Press and hold the Auto / Reset button again to display the Calibration Menu (FIG. 26, page 1

Strany 11 - Resettable Total (FIG. 11)

LDP5 Meter Setup and Operation Instructions312668W 19Units of Measurement (FIG. 25)Sets the units of measurement to gallons, quarts, pints, or liters.

Strany 12 - Calibration (FIG. 13)

Models 2 312668WModelsMeter Model No.ExtensionImpact GuardSwivel CoverInletRigid Flex NPT BSPT BSPPLDM5 255751XXLDM5 256215 X X X XLDM5 258693XXXXLDM5

Strany 13 - Operation

LDP5 Meter Setup and Operation Instructions 20 312668Wb. Press and hold the Manual / Reset button until CAL stops blink-ing. c. When CAL starts to bli

Strany 14 - Viewing Totals

LDP5 Meter Setup and Operation Instructions312668W 21Shut–Off Default Amount (FIG. 28)Prevents accidental overfills when dispensing with the trigger l

Strany 15 - Error Code

LDP5 Meter Setup and Operation Instructions 22 312668WOperationDispensing Fluid in Manual Mode (FIG. 29)1. Press and hold the Man-ual/Reset button.• I

Strany 16 - 16 312668W

LDP5 Meter Setup and Operation Instructions312668W 23Dispensing Fluid in Auto Mode (FIG. 30)1. Press and hold the Auto/Reset button.The display wakes

Strany 17 - Setup Menus (FIG. 23)

LDP5 Meter Setup and Operation Instructions 24 312668WViewing TotalsThis is the procedure for viewing the non–resettable and resettable totals. To cha

Strany 18 - Resettable Total (FIG. 24)

LDP5 Meter Setup and Operation Instructions312668W 25Error CodesError codes are listed below. Even in an error condition, the unit keeps track of the

Strany 19 - Calibration (FIG. 26)

Troubleshooting 26 312668WTroubleshootingRelieve Pressure Relief Procedure, page 5, before you check or repair the meter. Be sure all other valves an

Strany 20 - Auto Preset Amount (FIG. 27)

Troubleshooting312668W 27Meter leaks from Cover/Control Poor swivel (3)/hose connection. Apply PTFE tape (leave minimum 2 engaged threads uncovered fo

Strany 21 - 312668W 21

NOTES 28 312668WNOTES

Strany 22

Parts312668W 29PartsEM5/PM5 Upgrade Kits†Nozzle Extension Accessory Kits (FN 26)Thermal Relief Kits (page 5)FN Part No. Description Qty1 257350 CONTRO

Strany 23 - 312668W 23

Warnings312668W 3WarningsThe following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama-tion point s

Strany 24

Parts 30 312668WModels 255751, 255277, 258693, 258694,24F885, 24F886, 24F891, 24F892, 255751, 255277, 24F881, 24F883,24F887, 24F88926: Flexible Extens

Strany 25 - Error Codes

Service312668W 31ServiceReplacing the BatteryTo change the battery, remove the battery cover, and replace the old battery with a new battery (FIG. 34)

Strany 26 - Troubleshooting

Technical Data 32 312668WTechnical Data* Tested in No. 10W motor oil. Flow rates vary with fluid pressure, temperature and viscosity.** Battery requir

Strany 27 - 312668W 27

Notes312668W 33Notes

Strany 28 - 28 312668W

All written and visual data contained in this document reflects the latest product information available at the time of publication. Graco reserves th

Strany 29 - Thermal Relief Kits (page 5)

Warnings 4 312668WPERSONAL PROTECTIVE EQUIPMENTWear appropriate protective equipment when in the work area to help prevent serious injury, including e

Strany 30

Installation312668W 5InstallationTypical InstallationsFIG. 1 shows a typical hose reel installation. Dispense valves can also be installed on a consol

Strany 31 - Replacing the Filter

Installation 6 312668WPressure Relief ProcedureThe equipment stays pressurized until pressure is man-ually relieved. To reduce the risk of serious inj

Strany 32 - Technical Data

Installation312668W 74.a. Place the hose end (with no dispense valve connected) into a container for waste oil.b. Secure the hose in the container so

Strany 33 - 312668W 33

Installation 8 312668WInstalling Extension and Nozzle on Meter1. Thread the sealing nut (26c) onto the extension (26a).2. Thread extension into meter

Strany 34 - Graco Information

LDM5 Meter Setup and Operation Instructions312668W 9LDM5 Meter Setup and Operation InstructionsSetupTermsThe following terms are shown on the display